• Golden Samurai TD11-6KVA
< >
  • Golden Samurai TD11-6KVA

Golden Samurai TD11-6KVA

product power:4.8KW(千瓦)

product capacity:6KVA 【View products of the same capacity】

series:Power frequency TD series 【View the same series of products】

voltage input and output:Single input single output (220V:220V)

weight:65 kg( 公斤)

size(LWH):260*717*560 MM(毫米)13U

Shape classification:

  • Product Overview
  • For details
  • Installation Notes
  • Product Image
  • After-sales service
  • Documentation
  • product description:


    Golden Samurai TD series industrial frequency online UPS adopts advanced full DSP digital control


    System technology has realized the leap from analog to digital. Often appear in harsh environments


    Power outage, mains voltage is too high or too low, voltage drops instantaneously, or vibration reduction



    Oscillation, high voltage pulse, voltage fluctuation, surge voltage, spectral wave distortion, clutter interference, frequency



    Rate fluctuations and other conditions can provide reliable power protection, combined with the mature technology of high-frequency machines,







    Application areas:


    Medical equipment, industrial equipment, large and medium-sized data centers, network management enterprise server machines


    Harsh environments such as housing.









    Features:


    Advanced DSP digital control technology



    The use of advanced fully digital DSP control technology makes data processing more accurate and rapid, and the output performance will be more excellent.


    High machine reliability.



    Large LCD+LED display screen



    Fully considered humanized design, perfect combination of LCD+LED, Chinese and American display, rich and easy-to-understand display content,


    Poop. The LCD display panel does not have a switch protection device to avoid all kinds of problems caused by collision or accidental pressing, so that users can use


    The process is safer and more reliable.


    Highly guaranteed dual AC power input function



    Two sets of input from different power grids can be used for the main AC input power supply and the bypass AC input power supply, so that the user’s


    The power supply has been more fully guaranteed.



    Frequency and phase sequence adaptive system



    The output frequency can be set to 50Hz or 60Hz according to the mains frequency. The output phase sequence can be automatically tracked according to the input phase sequence


    Phase lock.



    Intelligent charging system



    Users can freely set the appropriate charging power on the LCD control panel according to the battery type, capacity and battery usage status.


    Stream (1-25A). The scientific charging method has fully extended the service life of the battery.


    More excellent electrical performance


    The efficiency of the whole machine is as high as 93%-94%, and the ECO mode is provided, which increases the efficiency to over 97%, which greatly reduces



    UPS power loss division. The full-bridge topology with output isolation transformer is adopted, which has stronger load capacity and impact resistance. Output load


    The power solid number reaches 0.8,



    Parallel function


    Support multiple UPS parallel redundancy (option).



    TD3.png




    1. Advanced DSP digital control technology

    Adopt advanced digital control technology to improve the stability and reliability of the machine. The ECO function maximizes the cost savings for customers.

    2. Large screen LCD+LED display in Chinese and English

    Perfect combination, display in Chinese and English, can display the content of input, output, battery voltage, load status, current, UPS working status and mode, temperature, model manufacturer number. Main parameters such as voltage, frequency, current, etc. of the machine can be set directly through the LCD display

    3. Dual AC power input

    The main AC input power and bypass AC input power can use two sets of inputs from different power grids. LCD+LED

    4. Generator mode

    Support generator input

    5. Parallel function

    8 UPSs are connected in parallel for redundancy.

    6. Strong load capacity

    It adopts full-bridge topology with output isolation transformer, which has stronger load capacity and impact resistance. And optional bypass output isolation transformer.

    7. Full-bridge inverter architecture:

    UPS adopts advanced DSP design, three-phase independent full-bridge inverter system design, its output voltage and phase are completely unaffected by three-phase unbalanced load, and can withstand 100% unbalanced load.

    8. The charging current can be set

    The user can freely set an appropriate charging current (1~50A) on the LCD according to the battery capacity. When the UPS is running at full load, the maximum charging current is 50A.

    9. Battery management function

    Mainly include battery failure detection, low battery, battery loss and other conventional functions.

    10. Frequency and phase sequence adaptive system

    50Hz or 60Hz;

    The output phase sequence can automatically track and lock according to the input phase sequence.

    11. Protection and alarm functions

    LCD, output contacts, etc. prompt in time, self-diagnosis function at startup; with protection functions such as overload protection, output short circuit, input overvoltage, lightning protection, and battery reverse connection.

    12. Powerful panel setting function

    Output voltage: 200/208/220/230/240Vac (phase voltage)

    Output frequency: 50Hz/60Hz

    Charging current: 1~50A

    Battery discharge time

    Timing boot

    Shutdown timer

    Working mode: ECO, EPO

    LCD Chinese and English setting input frequency: 40~70Hz

    It has a variety of alarm methods, which can be automatically set according to the mains frequency through sound, light, and output frequency.

    13. EPO emergency shutdown function

    Through the "Emergency Stop" button, the rectifier and inverter can be turned off, and the output (including bypass and inverter) can be blocked. This button can be used when an emergency occurs or cannot be shut down normally.

    14. Host monitoring and alarm function

    15. Smart slot expandability function (optional)

    You can choose USB card, AS400 card, CMC monitoring card, SNMP card, RS485 card, EMD environmental monitoring card.

    The UPS is equipped with an SNMP slot to realize the UPS remote monitoring function, with functions such as automatic alarm, UPS operation status and fault prediction and diagnosis, and operation time control.

    Output RS-232 and RELAY signal for computer system connection, support Windows 95/98/2000 / NT / ME / XP, NOVELL / SNMP / ASMP /LINUX and other software

    ?










    TD11 6KVA detailed parameter table

    Rated Capacity6KVA
    modelTD11 6K

    TD11 6KVA input parameters

    Rectifier typeIGBT rectification
    Rated voltage220Vac
    Input voltage range220Vac±25%
    Input frequency rangeFor 50HZ system: 46-54HZ; For 60HZ system: 56-64HZ
    Input power factor>=0.99

    TD11 6KVA output parameters

    Rated output power6KVA / 4.8KW
    Rated output voltage200/230
    The output voltageSynchronize with mains (mains mode); 50Hz ± 0.2% (battery mode)
    Way of workingOnline
    Output waveformSine wave
    Conversion time0ms
    Overload capacityWhen 105%±5%≤load, overload is pre-warned; when 105%±5%<load≤125%5%, transfer to bypass output after 2 minutes; 125%±5%<load≤150%±5%, 30 minutes Turn to bypass output later; when load >150%±5%, turn to bypass output after 500 milliseconds

    TD11 6KVA battery and running time

    battery modelMaintenance-free sealed lead-acid battery
    Standard machine backup time30 minutes to 8 hours optional
    Battery pack model-
    Typical battery charging time8 hours
    battery voltage192V

    TD11 6KVA system parameters and standards

    Installation methodTower
    Overall efficiencyUp to 85%
    Electromagnetic CompatibilityIEC EN62040-02
    Surge protectionIEC 61000-4-2.4.5 Level IV, IEC61000-4-3 Level III
    Protection typeIP20

    TD11 6KVA communication and management

    Interface portRS232, optional Wedpower card, AS400 card
    control panelLCD+LED status indication
    Audible alarmAlarm once every 4 seconds when mains power fails: special low battery alarm once every second

    TD11 6KVA physical index

    W560.00 mm
    D260.00 mm
    H717.00 mm
    weight65.00 KG
    colorblack

    TD11 6KVA  environment

    working environment0 - 40 °C
    Relative humidity0 - 95%
    Operating height0-1500 meters
    storage temperature-5 - 45 °C
    Storage relative humidity0 - 95%
    Storage height0-15000 meters
    Audible noise at 1 m from the surface of the device<50.00 dB

    TD11 6KVA warranty

    Standard warrantyRepair or replace within 3 years





    10KVA AC 220V input: AC 220V output

    Input parameters
    Input voltage220V AC (Single phase double wire)
    Enter the live wire diameter6mm2 (Square millimeter)
    Input zero wire diameter6mm2(Square millimeter)
    Input ground wire diameter6mm2(Square millimeter)
    Input air switch32A -1P (AC open)
    Output parameters
    The output voltage220V AC (Single phase double wire)
    Output wire diameter6mm2(Square millimeter)
    Output neutral wire diameter6mm2(Square millimeter)
    Output ground wire diameter6mm2(Square millimeter)
    Output MCB32A -1P (AC open)
    Battery parameters
    External battery MCB30A-2P (DC MCB)
    External battery wire diameter6mm2(Square millimeter)




    800×531
    Detail picture 4

    796×800

    Detail picture 3
    800×531

    Detail picture 2

    800×531

    Detail picture 1

    800×531

    Detail Figure 5
    800×531

    TD33-150KVA
    800×531

    TD33-150KVA
    800×531
    TD
    800×531

    TD33

    Backup model: One year warranty, one year warranty for built-in battery


    Online models: three-year warranty



    12V24AH capacity battery products: three-year warranty


    After-sales service contact information throughout the country: Contact us



    7*24 hours service telephone: 400-830-8833



    related product recommendation